Resultado da pesquisa (2)

Termo utilizado na pesquisa Giannico A.T.

#1 - Vasovagal tonus index in dog with myxomatous mitral valve disease, 37(10):1181-1186

Abstract in English:

ABSTRACT.- Brüler B.C., Giannico A.T., Dittrich G. & Sousa M.G. 2017. Vasovagal tonus index in dog with myxomatous mitral valve disease. Pesquisa Veterinária Brasileira 37(10):1181-1186. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Campus Agrárias, Juvevê, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: bbruler@gmail.com The vasovagal tonus index (VVTI) is a useful and assessable index, obtained from standard ECG recordings, that is used to estimate heart rate variability (HRV), and may provide valuable information regarding the likelihood of progression into congestive heart failure (CHF). In this paperwork, we investigated how the vasovagal tonus index (VVTI) behaves in dogs with naturally-occurring myxomatous mitral valve disease (MMVD) Electrocardiographic (ECG) recordings and echocardiographic data of 120 patients diagnosed with MMVD were reviewed. The VVTI was calculated from twenty consecutive RR intervals for each dog enrolled in the study. Lower VVTI values were found in MMVD patients in American College of Veterinary Internal Medicine (ACVIM) stage C compared with stages B1 and B2. Values were also lower in patients with severe cardiac remodeling. When a cut-off value of 6.66 is used, VVTI was able to discriminate MMVD patients in stage C from B1 and B2 dogs with a sensitivity of 70 per cent and a specificity of 77 per cent. MMVD dogs in which VVTI is lower than 6.66 are 30% more likely to develop congestive heart failure (CHF).

Abstract in Portuguese:

RESUMO.- Brüler B.C., Giannico A.T., Dittrich G. & Sousa M.G. 2017. Vasovagal tonus index in dog with myxomatous mitral valve disease. [Índice de tônus vasovagal em cães com doença mixomatosa da valva mitral.] Pesquisa Veterinária Brasileira 37(10):1181-1186. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Campus Agrárias, Juvevê, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: bbruler@gmail.com O índice de tônus vasovagal (ITVV) é uma ferramenta útil e acessível, obtida por meio de traçados eletrocardiográficos convencionais (ECG), utilizada para calcular a variabilidade da frequência cardíaca (VFC), podendo também fornecer informações valiosas referentes à probabilidade de desenvolvimento de insuficiência cardíaca congestiva (ICC). Neste trabalho, foi investigado como o ITVV se comporta em cães com degeneração mixomatosa da valva mitral (DMVM) de ocorrência natural, ECGs e exames ecocardiográficos de 120 pacientes diagnosticados com DMVM foram avaliados. O ITVV foi calculado a partir de 20 intervalos RR consecutivos para cada cão envolvido. Valores menores de ITVV foram encontrados em pacientes em estágio C de doença mitral pela classificação do American College of Veterinary Internal Medicine (ACVIM), comparado com pacientes em estágio B1 e B2. Valores também foram menores em pacientes com remodelamento cardíaco importante. Quando um valor de corte de 6,66 foi usado, o ITVV foi capaz de distinguir pacientes em estágio C de B1 e B2 com uma sensibilidade de 70 por cento e uma especificidade de 77 por cento. Cães com DMVM cujo ITVV é menor que 6,66 são 30% mais propensos a evoluírem para ICC.


#2 - Electrocardiographic values in marmosets (Callithrix penicillata), 33(7):937-941

Abstract in English:

ABSTRACT.- Giannico A.T., Somma A.T., Lange R.R., Andrade J.N.B.M., Lima L., Souza A.C. & Montiani-Ferreira F. 2013. [Electrocardiographic values in marmosets (Callithrix penicillata).] Valores eletrocardiográficos em saguis-de-tufo-preto (Callithrix penicillata). Pesquisa Veterinária Brasileira 33(7):937-941. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: amaliagiannico@uol.com.br Knowledge of cardiac parameters in experimental animal models is essential for comparative medical research. Our study aimed to establish electrocardiographic parameters and reference values for marmosets (Callithrix penicillata). Nineteen healthy adult marmosets were used. A combination of tiletamine and zolazepam was used for chemical restrained before performing electrocardiography (ECG). A computerized ECG machine was used. Values of the ECG parameters were a mean heart rate of 264±74 beats/min, a variation MCA between 60° and -90°, a mean P wave duration of 34±6ms and amplitude of 0.132±0.051mV, a mean PR interval duration of 56±11ms, a mean QRS complex duration of 35±7ms and amplitude of 0.273±0.269mV, a mean QT interval duration 130±26ms, ST segment was isoelectric (13 animals) and with elevation (six animals) and a mean T wave amplitude of 0.19±0.083mV and positive. There was no significant difference between males and females. Thus, the electrocardiographic parameters obtained in our study in marmosets can be used as a reference values to in other future researches, providing researchers electrocardiographic parameters that contribute with the literature.

Abstract in Portuguese:

RESUMO.- Giannico A.T., Somma A.T., Lange R.R., Andrade J.N.B.M., Lima L., Souza A.C. & Montiani-Ferreira F. 2013. [Electrocardiographic values in marmosets (Callithrix penicillata).] Valores eletrocardiográficos em saguis-de-tufo-preto (Callithrix penicillata). Pesquisa Veterinária Brasileira 33(7):937-941. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: amaliagiannico@uol.com.br O conhecimento de parâmetros cardíacos em animais modelo experimentais é essencial para a investigação médica comparativa. Nosso estudo teve como objetivo estabelecer parâmetros eletrocardiográficos e valores de referência para saguis-de-tufo-preto (Callithrix penicillata). Dezenove saguis-de-tufo-preto adultos saudáveis foram utilizados. Uma combinação de tiletamina e zolazepam foi empregada para contenção química antes da realização do exame eletrocardiográfico (ECG). Foi utilizado para o exame de ECG um equipamento computadorizado. Os valores dos parâmetros do ECG encontrados foram frequência cardíaca média de 264±74 bpm, uma variação do eixo cardíaco médio entre 60° e -90°, a duração da onda P média de 34±6ms e amplitude de 0,132±0,051mV, um intervalo PR com duração de 56±11ms, duração média do complexo QRS de 35±7ms e amplitude de 0,273±0,269mV, duração do intervalo QT de 130±26ms, segmento ST isoelétrico (13 animais) e com supradesnível (seis animais) e uma amplitude de onda T de 0,19±0,083mV e com polaridade positiva. Não houve diferença significativa entre machos e fêmeas. Os parâmetros eletrocardiográficos obtidos em nosso estudo em saguis-de-tufo-preto podem ser utilizados como referência em outras pesquisas futuras, oferecendo aos pesquisadores parâmetros eletrocardiográficos que contribuem com a literatura.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV